American Ductile Iron Pipe Home Page

Special Flanged Tees

AMERICAN Ductile Iron Flanged Fittings
AMERICAN Standard Special Flanged Tees
Tee Reducing on Run

Tee Reducing on Run | Tee Reducing on Run and Branch | Bull-Head Tee
Flanged Base Tees | Base Flange Details | To Top of Page

ADIP Table No. 6-8

Size in. Pressure
Rating
psi
Dimension in Inches Weight
lb
Run Branch T T1 H K J
30 x 12 30 250 1.03 0.75 25 23 25 1880
30 x 20 30 250 1.03 0.8 25 23 25 1935
30 x 24 30 250 1.03 0.89 25 25 25 2025
36 x 12 36 250 1.15 0.75 28 26 28 2775
36 x 24 36 250 1.15 0.89 28 26 28 2860
36 x 30 36 250 1.15 1.03 28 28 28 3000
42 x 12 42 250 1.28 0.75 31 30 31 3950
42 x 24 42 250 1.28 0.89 31 30 31 3925
42 x 30 42 250 1.28 1.03 31 31 31 4130
42 x 36 42 250 1.28 1.15 31 31 31 4265
48 x 12 48 250 1.42 0.75 34 34 34 5305
48 x 42 48 250 1.42 1.28 34 34 34 5720
54 x 12 54 250 1.05 0.75 39 37 39 5360
54 x 36 54 250 1.05 1.15 39 37 39 5685
54 x 42 54 250 1.05 1.28 39 39 39 5980
54 x 48 54 250 1.05 1.42 39 39 39 6210

Notes:
*Tees reducing on run are available in 30" and larger sizes only.
Numerals on cuts indicate standard order of specifying size of fitting.
Additional combination reductions can be furnished. Center-to-face dimensions will be according to ANSI B16.1 Class 125. See Table No. 6-2.
Other end combinations such as MJ, Fastite, Lok-Ring, or Flex-Ring can be furnished.
See General Notes.


AMERICAN Ductile Iron Flanged Fittings
AMERICAN Standard Special Flanged Tees
Tee Reducing on Run and Branch

Tee Reducing on Run | Tee Reducing on Run and Branch | Bull-Head Tee
Flanged Base Tees | Base Flange Details | To Top of Page

ADIP Table No. 6-9

Size in. Pressure
Rating
psi
Dimension in Inches Weight
lb
Run Branch T T1 H K J
30 x 12 12 250 1.03 0.75 25 23 23 1610
30 x 12 20 250 1.03 0.8 25 23 23 1665
30 x 12 24 250 1.03 0.89 25 23 25 1755
30 x 20 12 250 1.03 0.75 25 23 23 1665
30 x 20 20 250 1.03 0.8 25 23 23 1715
30 x 20 24 250 1.03 0.89 25 23 25 1805
30 x 24 12 250 1.03 0.75 25 25 23 1755
30 x 24 20 250 1.03 0.8 25 25 25 1835
30 x 24 24 250 1.03 0.89 25 25 25 1895
36 x 12 12 250 1.15 0.75 28 26 26 2385
36 x 12 24 250 1.15 0.89 28 26 26 2470
36 x 12 30 250 1.15 1.03 28 26 28 2615
36 x 24 12 250 1.15 0.75 28 26 26 2385
36 x 24 24 250 1.15 0.89 28 26 26 2555
36 x 24 30 250 1.15 1.03 28 26 28 2695
36 x 30 12 250 1.15 0.75 28 28 26 2615
36 x 30 24 250 1.15 0.89 28 28 26 2695
36 x 30 30 250 1.15 1.03 28 28 28 2840
42 x 12 12 250 1.28 0.75 31 30 30 3430
42 x 12 24 250 1.28 0.89 31 30 30 3505
42 x 12 30 250 1.28 1.03 31 30 31 3610
42 x 24 12 250 1.28 0.75 31 30 30 3505
42 x 24 24 250 1.28 0.89 31 30 30 3580
42 x 24 30 250 1.28 1.03 31 30 31 3690
42 x 30 12 250 1.28 0.75 31 31 30 3610
42 x 30 24 250 1.28 0.89 31 31 30 3690
42 x 30 30 250 1.28 1.03 31 31 31 3795
48 x 12 12 250 1.42 0.75 34 34 34 4715
48 x 12 42 250 1.42 1.28 34 34 34 5130
48 x 42 12 250 1.42 0.75 34 34 34 5130
48 x 42 42 250 1.42 1.28 34 34 34 5540
54 x 12 12 250 1.05 0.75 39 37 37 4690
54 x 12 36 250 1.05 1.15 39 37 37 5015
54 x 12 42 250 1.05 1.28 39 37 39 5310
54 x 36 12 250 1.05 0.75 39 37 37 5015
54 x 36 36 250 1.05 1.15 39 37 37 5345
54 x 36 42 250 1.05 1.28 39 37 39 5635
54 x 42 12 250 1.05 0.75 39 39 37 5310
54 x 42 36 250 1.05 1.15 39 39 37 5635
54 x 42 42 250 1.05 1.28 39 39 39 5930

Notes:
*Tees reducing on runs and branches are available in 30" and larger sizes only.
Numerals on cuts indicate standard order of specifying size of fitting.
Additional combination reductions can be furnished. Center-to-face dimensions will be according to ANSI B16.1 Class 125. See Table No. 6-2.
Other end combinations such as MJ, Fastite, Lok-Ring, or Flex-Ring can be furnished.
See General Notes.


AMERICAN Ductile Iron Flanged Fittings
AMERICAN Standard Special Flanged Tees
Bull-Head Tee

Tee Reducing on Run | Tee Reducing on Run and Branch | Bull-Head Tee
Flanged Base Tees | Base Flange Details | To Top of Page

ADIP Table No. 6-10

Size in. Pressure
Rating
psi
Dimension in Inches Weight
lb
Run Branch T T1 H J
30 x 30 36 250 1.03 1.15 28 28 2840
30 x 30 54 250 1.03 1.05 37 39 5075
36 x 36 42 250 1.15 1.28 31 31 4060
36 x 36 54 250 1.15 1.05 37 39 5345
42 x 42 48 250 1.28 1.42 34 34 5540
42 x 42 54 250 1.28 1.05 39 39 5930
48 x 48 54 250 1.42 1.05 39 39 6400

Notes:
*Bull-head tees are available in 30" and larger sizes only.
Numerals on cuts indicate standard order of specifying size of fitting.
Additional combination reductions can be furnished. Center-to-face dimensions will be according to ANSI B16.1 Class 125. See Table No. 6-2.
Other end combinations such as MJ, Fastite, Lok-Ring, or Flex-Ring can be furnished.
See General Notes.


AMERICAN Ductile Iron Flanged Fittings
ANSI/AWWA C110/A21.10 or C153/A21.53
Flanged Base Tees

Tee Reducing on Run | Tee Reducing on Run and Branch | Bull-Head Tee
Flanged Base Tees | Base Flange Details | To Top of Page

ADIP Table No. 6-20

Size
in.
Pressure
Rating
psi
Dimensions in Inches Weight in Pounds
R S
Dia.
T U Base
Fitting
Base
Only
4 250 5.5 6 0.62 0.5 75 10
6 250 7 7 0.69 0.62 110 15
8 250 8.38 9 0.94 0.88 185 30
10 250 9.75 9 0.94 0.88 300 30
12 250 11.25 11 1 1 430 45
14 250 12.5 11 1 1 485 50
16 250 13.75 11 1 1 600 50
18 250 15 13.5 1.12 1.12 740 75
20 250 16 13.5 1.12 1.12 930 75
24 250 18.5 13.5 1.12 1.12 1410 80
30 250 23 16 1.19 1.15 2270 120
36 250 26 19 1.25 1.15 3320 160
42 150 30 23.5 1.44 1.28 4740 270
42 250 30 23.5 1.44 1.28 5850 270
48 150 34 25 1.56 1.42 6235 335
48 250 34 25 1.56 1.42 7720 335
*54 250 38 27.5 1.69 1.55 6590 565
*60 250 42 32 1.88 1.75 8905 855
*64 250 44 38.75 2.12 1.75 12275 1275

Notes:
*Not included in AWWA C110 or C153.
Bases are faced and drilled only when specified. Dimension "R" is finished dimension; unfinished bases will be slightly longer. For supporting pipe sizes see Table No. 6-22.
For base drilling see Table No. 6-21.
See tables on preceding pages for dimensions and weights of all tees. Base dimensions and weights are the same for full opening tees and for reducing tees. Proper base is determined by largest opening. To compute total weight of reducing base tee, add weight of base only (shown above) to weight of reducing tee of size and class as selected from preceding tables. To order base tees reducing on the branch, specify sizes in proper order and give figure number shown above. Bases other than shown above - such as on the side of fitting - are special and may be available on 30" and larger bends. Some available base locations are shown on the tapped holes and sequence of openings page. Check AMERICAN for special base locations.
Bases of these fittings are intended for support in compression and are not to be used for thrust anchors or supports in tension, bending, or shear.
See General Notes.


AMERICAN Ductile Iron Flanged Fittings
ANSI/AWWA C110/A21.10 and AMERICAN Standard
Base Flange Details

Tee Reducing on Run | Tee Reducing on Run and Branch | Bull-Head Tee
Flanged Base Tees | Base Flange Details | To Top of Page

ADIP Table No. 6-21

Fitting
Size
in.
Dimensions in Inches No.
of
Bolts
B.C.
Bolt Circle
Bolt
Hole
Diameter
4 4.75 3/4 4
6 5.5 3/4 4
8 7.5 3/4 4
10 7.5 3/4 4
12 9.5 7/8 4
14 9.5 7/8 4
16 9.5 7/8 4
18 11.75 7/8 4
20 11.75 7/8 4
24 11.75 7/8 4
30 14.25 1 4
36 17 1 4
42 21.25 1 1/8 4
48 22.75 1 1/4 4
*54 25 1 1/4 4
*60 29.5 1 3/8 4
*64 36 1 3/8 4

Notes:
*These sizes are not included in AWWA C110 or C153.
BASE FACED AND DRILLED: Bases are not faced or drilled unless so specified on the purchase order. When a base fitting is ordered with base faced and drilled, base will be plain faced and drilled as shown in the table.
For supporting pipe sizes see Table No. 6-22 (below). See Table No. 6-19 on the flanged 90 bends page and 6-20 (above) for additional base dimensions.
See General Notes.

Size of Supporting Flanged Pipe for Base Fittings

ADIP Table No. 6-22

Fitting
Size-Inches
4 5 6 8 10 12 14 16 18 20 24 30 36 42 48 54 60 64
Supporting
Pipe Size-Inches
2 2 1/2 2 1/2 4 4 6 6 6 8 8 8 10 12 16 18 20 24 30

To Top of Page

> Tee Reducing on Run 
>
Tee Reducing on Run and Branch 
>
Bull-Head Tee
> Flanged Base Tees 
>
Base Flange Details


 
 

© 1995 – 2008, American Cast Iron Pipe Company