American Ductile Iron Pipe Home Page

Outlet/Tapping Saddles

AMERICAN Ductile Iron Specials
Outlet/Tapping Saddles

MJ Outlet Flange Outlet



Saddle is furnished with AWWA C110 flange or mechanical joint outlet and can be installed on pipe with hole already machine cut or torch cut at shop or at job site. Saddle can thus be used on 12" through 54" pipe for providing outlet as pipeline is being installed or in pipeline already installed. For a saddle in sizes 4" through 12" with AWWA C110 flange connection on the branch, the flange is counterbored per MSS (Manufacturers' Standardization Society) SP-60 dimensions, making assembly possible with a tapping machine, tapping valve, or a standard C110 flange. The inside diameter of the outlet is 1/4" greater than the nominal, enabling a full-size opening to be made in pipe wall. Counterbore dimensions are as tabulated in Table No. 7-14 (see right).            

ADIP Table No. 7-14

Size of
Flange
in.
Counterbore
Depth
in.
Diameter
in.
4 0.25 5.015
6 0.312 7.015
8 0.312 9.015
10 0.312 11.015
12 0.312 13.015



ADIP Table No. 7-15

Size
in.
O.D.
of Parent
Pipe
in.
C.
in.
No. of
Straps
Weight in Pounds
Saddle
Casting
Straps
& Nuts
Total
12 x 4 13.2 12.85 3 45 15 60
12 x 6 13.2 12.85 3 62 14 75
14 x 4 15.3 13.9 3 45 17 60
14 x 6 15.3 13.9 3 62 16 80
16 x 4 17.4 14.95 3 45 19 65
16 x 6 17.4 14.95 3 62 18 80
16 x 8 17.4 14.95 4 89 24 115
18 x 4 19.5 16 3 45 22 65
18 x 6 19.5 16 3 62 21 85
18 x 8 19.5 16 4 89 26 115
20 x 4 21.6 17.05 3 45 23 70
20 x 6 21.6 17.05 3 62 23 85
20 x 8 21.6 17.05 4 89 29 120
20 x 10 21.6 17.05 5 120 35 155
24 x 4 25.8 19.15 3 45 27 70
24 x 6 25.8 19.15 3 62 27 90
24 x 8 25.8 19.15 4 89 35 125
24 x 10 25.8 19.15 5 120 42 160
24 x 12 25.8 19.15 7 151 58 210
30 x 4 32 22 3 45 34 80
30 x 6 32 22 3 62 34 95
30 x 8 32 22 4 89 43 130
30 x 10 32 22 5 120 53 175
30 x 12 32 22 7 151 72 225
36 x 4 38.3 25.25 3 45 40 85
36 x 6 38.3 25.25 3 62 40 100
36 x 8 38.3 25.25 4 89 52 140
36 x 10 38.3 25.25 5 120 64 185
36 x 12 38.3 25.25 7 151 88 240
42 x 4 44.5 28.25 3 45 46 90
42 x 6 44.5 28.25 3 62 46 110
42 x 8 44.5 28.25 4 89 60 150
42 x 10 44.5 28.25 5 120 74 195
42 x 12 44.5 28.25 7 151 102 255
48 x 4 50.8 31.5 3 45 53 100
48 x 6 50.8 31.5 3 62 52 115
48 x 8 50.8 31.5 4 89 69 160
48 x 10 50.8 31.5 5 120 85 205
48 x 12 50.8 31.5 7 151 117 270
54 x 4 57.56* 34.55 3 45 59 105
54 x 6 57.56* 34.55 3 62 58 120
54 x 8 57.56* 34.55 4 89 77 165
54 x 10 57.56* 34.55 5 120 95 215
54 x 12 57.56* 34.55 7 151 132 285

Notes:
Weights are for Saddle with MJ bell or AWWA C110 flange; weights do not include any MJ or flange joint materials.
Saddles listed are rated 250 psi working pressure. Check AMERICAN for higher pressure applications.
Straps are alloy steel, 1/4" X 1 1/2" in cross section and are fabricated with 3/4" threaded ends. Sealing of Saddle is provided by a positively confined "O-Ring" SBR rubber gasket, circular in cross section and made of molded rubber approximately 70 Durometer Hardness.
Saddles to fit some other diameters can be furnished upon request. Order should specify diameter of parent pipe.
Outlet can be furnished tapped for studs when specified.
Maximum size outlet normally furnished for tapping 12"-14" pipe is 6"; for 16"-18" pipe is 8"; for 20" pipe is 10"; and for 24"-54" pipe is 12".
On special order some outlets 14" through 18" can be furnished for low pressure service on 30"-54" pipe.
See General Notes.
*Prior to 1988, 54" AMERICAN pipe had an O.D. of 57.10". Installers should measure the O.D. of existing 54" pipe prior to ordering so that proper strap lengths can be furnished.


For recommended minimum installation distance (X) from face of Fastite bell to center of saddle, see Table No. 7-16.

           

ADIP Table No. 7-16

Size
in.
"X"
Min.
12 x 6 12
14 x 6 14
16 x 8 14
18 x 8 16
20 x 10 16
24 x 12 18
30 x 12 18
36 x 12 18
42 x 12 20
48 x 12 20
54 x 12 20



 
 

© 1995 – 2008, American Cast Iron Pipe Company